Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13776364
- Product Categories
- Small gasoline generators
- Silent diesel generator
- Electric welding machine
- Digital Inverter Generator
- Gasoline pumps
- Diesel pumps
- Friendly Links
Information Name: | Ito welding machine YT6800EW |
Published: | 2015-06-10 |
Validity: | 301 |
Specifications: | Welding machine |
Quantity: | 439.00 |
Price Description: | |
Detailed Product Description: | Company Name: Hay on the transcript Industrial Co., Ltd. Brand: Original Ito Power Company Address: Changji Road, Jiading District, Shanghai Volkswagen Creative Park Contact: Euro Manager Tel: 177-1769-7404 / 180-1712-0387 Online QQ: 568,477,135 transactions: the purchase and sale contract payment transaction trading patterns: transfer, Paypal, cash, check, credit card about the product: 17% VAT, excluding shipping, nationwide 24-hour delivery. Main: gasoline generator, digital inverter silent generators, diesel generators, pump, power welding, gas generators, road cutting machines "190A diesel welding machine Product Code YT6800EW frequency 50HZ rated current of 190A rated power 1.8KW (generator section) Maximum output power 2.0KW (generator part) generator rated voltage 230V (generator part) Starting method Hand / electric start, self-exciting DC excitation mode Phase Single phase alternate power supply is 220 volts DC welding current Engine model LD186FA Engine type air-cooled diesel fuel displacement volume 15L fuel 0.418CC about 271g / kw * h oil volume in the form of 1.65L structure open-shelf | Trolley type Dimensions (MM) 725 * 500 * 630 NW / GW (KG) 102 | 110KG Cooling Forced air cooling Rated power current 8A 180A welding current excitation mode excitation loop manner from the DC circuit common electrode welding 3.2 4.0 Maximum welding electrode AC output DC output There Has Has diesel has a maximum output power [hp]: 8.8 / 9.6 Diesel continued Output Power [hp]: 7.7 / 8.6 diesel welding machine DC welding machine :(, Auxiliary Power: AC voltage) A: 190A diesel welding machine, *** yuan | Taiwan, model YT6800EW, electric start without battery The main welding: welding 3.2mm-4.0mm or less (welding diameter) gasoline generator petrol generator home http://www.shytdlfdj.com car http://www.yzfadianji.com silent generator http: // luogankongyajizu .b2b.bestb2b.com / 5 千瓦 silent diesel generator http://xiaoqiyoufadianjizu.cn.jvrong.com/ gasoline welding machine http://www.goepe.com/apollo/prolist-kanliya-2245592-1.html Diesel pump http://www.goepe.com/apollo/prolist-keerkang2012-2245600-1.html silent diesel generator sets http://www.goepe.com/apollo/prolist-bao123456-2245606-1.html Small Price http://shop1432812021694.1688.com/ automatic diesel generator petrol generator http://wlq760344132.b2b.bestb2b.com Silent diesel generator set http://kongyaji22kw.cn.jvrong.com Company Name: Shanghai Iraqi transcript Industrial Co., Ltd. brand - Ito Power Contact: Ouyang Feng (Manager) Sales Tel: 021-60953542 Technology: 177-1769-7404 E-mail: 568477135@qq.com Direct Address: Anting Town, Jiading District, Shanghai Changji Road 156, Lane Company Website: http://www.yzfadianji.com/ Repairs one year warranty and lifetime maintenance recommended reason quality, low fuel consumption, simple operation, service, construction, emergency, backup choice Select Common diesel generator sets? ???? some diesel generator or often take a long time continuously at a certain time, to serve as a common electricity load power supply, such generators commonly called generators. Commonly used generator sets as a common unit and standby unit. Away from the big grid of towns, islands, forest, mining, oil and other areas or mining enterprises, in order to supply local residents plant health and life of electricity, you need to install diesel generators, these generators usually should be uninterrupted. Important facilities? ??? Defense engineering, communications hub, radio stations, microwave relay stations, etc., shall be provided with backup diesel generators. Such facilities usually be mains electricity power grid supply. However, due to other natural disasters such as earthquakes, typhoons, war or human factors, so that the city power grid destroyed and later, has been set standby unit should start quickly, and adhere to long-term continuous manner, to ensure that these important projects for electricity continuous power load, which backup generators are also commonly used types of generators. Common generators continue to work for a long time, the load curve changes greatly in different ways to control the unit capacity, the number of units and unit type selection and emergency unit. ? OK ??? 1. Common diesel generator capacity, long-term continuous operation by the unit output power to meet the computational load-wide maximum choice, and backup generators should determine the load capacity of the units in accordance with the importance. Output power diesel ongoing, typically 0.9 times the rated power. ? 2. diesel generator sets used to determine the number of units? ??? Number of units used diesel generator set is usually two or more, in order to ensure continuity of supply and adapt to changes in the electricity load curve. Units Number of units more, it can determine the number of units generating units were put under electricity load changes, so that the diesel engine is often running in the economic load, in order to reduce fuel consumption, reduce the cost of electricity. The best economic operating state of the diesel engine is between 75% -90% of rated power. In order to ensure continuity of supply, common unit itself should consider setting up reserve units, when the unit troubleshooting, or stop to check the sets will still be able to meet important continuous power supply uninterrupted electricity load. ? 3. Common diesel generator set speed determined? ??? In order to reduce wear and increase the service life of the unit, used generators should use the rated speed of not more than 1000r / min, the low-speed unit, its optional standby unit, the high speed unit. The same power plant units should use the same model and capacity of the unit in order to use the same spare parts, easy maintenance and management. Load changes of project, you can use the same series of groups of different capacities. Generator output voltage to determine the calibration and emergency generators same, usually 400V, individual large electricity, transmission distance of high voltage engineering can be used generators. ? ??? Common control unit 4. Common diesel generator sets should generally be considered can be connected in parallel to simplify power distribution main wiring, the unit start, stop rotation running through and the car, load transfer switch without interrupting the power supply unit . Unit should be fitted with measurement and control devices of the unit, the governor and excitation unit adjusting device shall be connected in parallel with the applicable requirements of the fish. Important load power supply standby generator sets, diesel generator sets should use automated external power failure after power failure, automatic start quickly restore power to the important load. Engine running very noisy room, automated unit compartment to facilitate the transformation of operation, automatic monitoring of generator sets. When the generator set normally, the operator does not have to enter the diesel engine room, the control room can be monitored on the diesel generator. ? ???? Five diesel generator sets in the order requirement ??? make the options above, order diesel generator sets should generally indicate the following:?? References (1) of the unit, rated power, rated frequency , rated voltage, rated current, phase, power factor and wiring methods. ? (2) on the unit automation and performance requirements. ?? (3) of the diesel engine, generator and control panel configuration, performance, installation size requirements. ?? (4) requirements for units operating in parallel: while purchase more than one unit, if the requirements of parallel conduct, such as the need for parallel conduct, but also put forward the need to provide the required measuring instruments and devices in parallel. ?? (5) requirements for ancillary equipment units: Many domestic manufacturers to the cooling water tank (radiator), fuel tank, exhaust muffler, batteries and other ancillary equipment to be regarded as allowing some proposed requirements for the installation when ordering. |
Admin>>>
You are the 10337 visitor
Copyright © GuangDong ICP No. 10089450, Ito generator Shanghai Machinery Manufacturing Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10337 visitor
Copyright © GuangDong ICP No. 10089450, Ito generator Shanghai Machinery Manufacturing Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility